| A1. |
Itfs 133,195 mm3
(133.2 cc).
The compressed air requirements for all housings of the
MC6 series (cylinder volume~2) are
the same. With respect to air consumption, the definition from the perspective
of checking the supply capacity of compressor is appropriate. In this case, the
compressed air requirement is calculated as the discharge air volume required
for the compressor using the following formula for converting intake air volume
at one atmosphere:
Q = 2 x V x ((P + 0.1013)/0.1013)
x 1.3 x N
[Q = Required discharge air volume (L/min), V =
Cylinder volume of the tool, P = Supply pressure (MPa), N = Operation frequency
(every minute) and 0.1013 is 1 atmosphere in MPa.]
For example, if
this calculation is for 10 shots/minute at 0.6 MPa supply pressure,Q = 0.133195 x
((0.6+0.1013)/0.1013) x 1.3 x 10 = 11.99 (L/min).
Air consumption per one shot is, that is to say,
approximately 1.2 L (1.199 cc) at (0.6 MPa). |